Your excellent helper in cable test!
12
Open: Master unit and Remote unit both no connected
pins LEDs are off. (Fig 8.)
Short: Master unit testing short pin LEDs brighter
than others. Remote unit shorted pins LEDs are off.
(Fig 9.)
Crossover: It can't be tested on this mode.
Master unit with Remote unit slow continuity
scan testing function:
1.Press “ TEST button during LED indicate automatic
testing result or Press twice “ TEST” button before LED
off for perform automatic testing, it will continually scan
#1~#19 pin and shield conductor. Master unit and
Remote unit both #1~19 and Shield LEDs will light up in
sequence very slow and sustained repeated automatic
scan.
2.LED indicate testing result as below
: Master unit and Remote unit both testing
pins #1~19 and Shield LEDs are all lighted up in sequence.
(Fig 7.)
Open: Master unit and Remote unit both LEDs are
off when scan to no connected pins, others LEDs are
all lighted up in sequence. Example : Test HDMI
(A Type) to HDMI (A Type) cable that pin #2#5#8
#11 are not connected, or test HDMI (A Type) to
Mini-HDMI (C Type) cable that pin #1#4#7#10
are not connected, or test Mini-HDMI (C Type) to
Mini-HDMI (C Type) cable that pin #1#4#7#10
are not connected. (Fig 8.)
Straight
Seitenansicht 12